Pelco - ALM2064.
Request Quote

Alarm Interface Unit for CM6800 Series Matrix System

Model: ALM2064.

  • 64 alarm contact inputs
  • Connects to the CM6800 series matrix switchers using Pelco M-protocol
  • Uses RS-485 communication interface
  • Multiple units can be cascaded to provide multiple alarm contact points on single M-Port connection
  • Alarm inputs can be configured for supervised or unsupervised mode
Compare
Project List
Product Info
Tech Specs
Documents
The ALM2064 alarm interface unit connects directly to the System 6800 matrix switcher/controller. Each unit provides monitoring capability for up to 64 external alarm inputs. Using Pelco’s proprietary M protocol, the alarm unit communicates with Pelco’s CM6800 matrix switchers through an RS-485 communication interface.

The alarm unit can be located remotely from the system controller and still communicate back to the central system when an alarm occurs. Up to four alarm interface units can be cascaded to provide multiple alarm contact points on a single M-port connection. Alarm inputs on each ALM2064 unit can be configured in two groups of 32 each for supervised/unsupervised mode.

The ALM2064 provides a relay output on the rear panel. The alarm unit will activate a peripheral device connected to this output when a valid alarm condition is sensed.

  • 64 alarm contact inputs
  • Connects to the CM6800 series matrix switchers using Pelco M-protocol
  • Uses RS-485 communication interface
  • Multiple units can be cascaded to provide multiple alarm contact points on single M-Port connection
  • Alarm inputs can be configured for supervised or unsupervised mode
  • Supports imports from normally open (N.O.) or Normally Closed (N.C.) contacts
  • 100 to 240V AC, 50/60 Hz, auto-ranging input voltage
 